Ugrás a tartalomra

9300

The intelligent drives in the 9300 range are ideally suited to independently control sub-processes within a machine. Starting from precustomised standard applications, individual extensions are easy to implement with the help of freely connectible function blocks – which reduces the load on the control system and facilitates modular machine design.

The 9300 series servo inverters can be used universally in the power range from 0.37 to 75 kW.

To comply with the most diverse of requirements in terms of the servo technology, the following four versions are available:

  • 9300 servo inverter
  • 9300 servo position controller
  • 9300 servo cam
  • 9300 servo register controller

Using a uniform user interface reduces training requirements. Staff only need to learn one system, which can then be used for all applications. The pluggable AIF communication modules also allow easy integration into common fieldbus systems. The devices are optionally available with the integrated "safe torque off" function.

Kép
    Products
    Title Rated power Manufacturer SKU Price
    EVS9321 0.37 kW Lenze EVS9321 2 360,00 EUR
    EVS9322 0.75 kW Lenze EVS9322 2 860,00 EUR
    EVS9323 1.5 kW Lenze EVS9323 3 260,00 EUR
    EVS9324 3 kW Lenze EVS9324 3 760,00 EUR
    EVS9325 5.5 kW Lenze EVS9325 4 280,00 EUR
    EVS9326 11 kW Lenze EVS9326 4 980,00 EUR
    EVS9327 15 kW Lenze EVS9327 7 890,00 EUR
    EVS9328 22 kW Lenze EVS9328 11 860,00 EUR
    EVS9329 30 kW Lenze EVS9329 14 890,00 EUR
    EVS9330 45 kW Lenze EVS9330 18 690,00 EUR
    EVS9331 55 kW Lenze EVS9331 19 690,00 EUR
    EVS9332 75 kW Lenze EVS9332 22 360,00 EUR
    Documentation
    Title Language Document type Version File
    System manual 93xx-ES EN Manuals 1.0
    Operating Instructions EVS93xx-EP EN Operating instructions 2.3
    System manual extension EVS93xx EN Manuals 2.0
    System manual EVS93xx EN Manuals 6.0
    Commissioning Lenze 9300 EN Commissioning 3.0
    Mounting Instructions Lenze 9300 EN Mounting instructions TD29
    PROFIBUS - EMF2133IB EN Operating instructions EN 5.0 TD14
    POWERLINK - EMF2191IB EN Operating instructions EN 2.0 TD17
    ModemCAN - EMF2181IB EN Operating instructions EN 3.0 TD17
    Interbus - EMF2111IB EN Operating instructions EDSIBS-1.0-06/2003
    Remote Maintenance - EMF2180IB EN Operating instructions DMS 5.1 EN · 09/2016 · TD17
    DeviceNet - EMF2175IB EN Operating instructions EDSDEN EN 02/2006
    CANopen - EMF2178IB EN Operating instructions EDSCAN-1.0-06/2003
    Keypad - EMZ9371BB EN Operating instructions 2.0
    Project planning 9300 servo inverter EN Project planning 03/2009
    Error codes
    Fault ID: 12816
    Hex: 0x3210
    Description: Fault - DC bus overvoltage
    Keypad display: DC Bus OV
    Cause Remedy Severity/response

    DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01).

    Reduce dynamic performance of the load profile.

    Check mains voltage.

    Check settings for brake energy
    management.

    0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper

    Fault

    Fault ID: 12672
    Hex: 0x3180
    Description: UPS operation active
    Keypad display: UPS oper. active
    Cause Remedy Severity/response

    Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided.

    Switch back to operation with regular mains voltage

    Warning

    Fault ID: 12576
    Hex: 0x3120
    Description: Mains phase fault 
    Keypad display: Mains Phase fail
    Cause Remedy Severity/response

    Mains phase failure

    • Check wiring of the mains connection.
    • Check fuses.

    Fault

    Fault ID: 1030
    Hex: 1030
    Description: Undervoltage in the DC bus
    Keypad display: LU
    Cause Remedy Severity/response

    DC bus voltage is lower than specified in C0173.

    • Check mains voltage
    • Check supply cable

    cawc

    Fault ID: 1020
    Hex: 1020
    Description: Overvoltage in DC bus
    Keypad display: OU
    Cause Remedy Severity/response

    Braking energy is too high. (DC−bus voltage is higher than set in C0173.)

    • Use braking unit or regenerative module.
    • Check dimensioning of the brake resistance.
    Fault ID: 0016
    Hex: 0016
    Description: I2xt overload
    Keypad display: OC6
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: x018
    Hex: x018
    Description: I2xt overload advance warning
    Keypad display: OC8
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: 0015
    Hex: 0015
    Description: I x t overload
    Keypad display: OC5
    Cause Remedy Severity/response
    • Frequent and too long acceleration with overcurrent
    • Continuous overload with Imotor > 1.05 x Irx

    Check drive dimensioning.

    Fault ID: 0012
    Hex: 0012
    Description: Motor cable earth fault
    Keypad display: OC2
    Cause Remedy Severity/response

    One of the motor phases has
    earth contact.

    • Search for cause of short circuit.
    • Check motor cable.
    Fault ID: 0011
    Hex: 0011
    Description: Short circuit of motor cable
    Keypad display: OC1
    Cause Remedy Severity/response

    Short circuit

    Excessive capacitive charging
    current in the motor cable.

    • Search for cause of short circuit.
    • Check motor cable.

      Use motor cable which is shorter
      or of lower capacitance.

    Fault ID: 9090
    Hex: 0x2382
    Description: Fault - Device utilization (ixt) too high
    Keypad display: Ixt error
    Cause Remedy Severity/response

    Device utilisation (ixt) too high by frequent and too long acceleration processes.

    Check drive sizing. 

    • Reduce the maximum current of the inverter 0x6073 (P324.00). 
    • In case of high mass inertias, reduce maximum current of the inverter 0x6073 (P324.00) to 150 %.

    Fault (configurable)

    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Setting parameters: 0x2D40:005 (P135.05)

    Fault ID: 9040
    Hex: 0x2350
    Description: CiA: i²xt overload (thermal state)
    Keypad display: i2t motor
    Cause Remedy Severity/response

    Motor thermally overloaded, e. g. by an impermissible continuous current or by frequent or too long acceleration processes.

    Check drive sizing.

    • Check machine/driven mechanics for excessive load.
    • Check settings of the motor data.
    • Reduce values for slip compensation 0x2B09:001 (P315.01), 0x2B09:002 (P315.02) and oscillation damping 0x2B0A:001 (P318.01), 0x2B0A:002 (P318.02).

    Fault (configurable)

    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Setting parameters: 0x2D4B:003 (P308.03)

    Fault ID: 9024
    Hex: 0x2340
    Description: Short circuit at the motor end
    Keypad display: Motor shorted
    Cause Remedy Severity/response

    Short circuit of motor cable

    Check motor cable for short circuit.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Fault ID: 8992
    Hex: 0x2320
    Description: Short circuit or earth leakage at the motor end
    Keypad display: Earth leak
    Cause Remedy Severity/response
    • Short circuit/earth fault of motor cable
    • Capacitive charging current of the motor cable too high.
    • Check motor cable.
    • Check length of the motor cable.
    • Use shorter or lower-capacitance motor cable.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Fault ID: 8784
    Hex: 0x2250
    Description: CiA: Continuous over current (internal)
    Keypad display: PU over current
    Cause Remedy Severity/response
    • Continuous overcurrent on the inverter/ motor side.
    • Overcurrent at the brake chopper (brake transistor).
    • DC bus relay has not been closed due to a malfunction.
    • Check motor and wiring for short circuits.
    • Check brake resistor and wiring.
    • Check motor switching.
    • Check settings of the motor data.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s