Remedy
1. Check user parameter settings. (The loaded backup is an older version.) 2. If required, repeat the changes made last. 3. Execute device command "Save user data" 0x2022:003 (P700.03).
Cause
Saving of the parameter settings was interrupted by an unexpected disconnection.
Description
Data not compl. saved before powerdown
Keypad display
Save incomplete
Severity/response
Warning
- The user parameter settings were not fully saved.
- At the next switch-on, the data stored are copied to the user memory.