0x2631:035 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:035 Parameter Function list: Stop sequence Default setting Not connected [0] M - A P C Data type U8 Display Code P400.35 Factor 1
0x2631:034 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:034 Parameter Function list: Suspend sequence Default setting Not connected [0] M - A P C Data type U8 Display Code P400.34 Factor 1
0x2631:037 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:037 Parameter Function list: Activate network control Default setting Not connected [0] M - A P Data type U8 Display Code P400.37 Factor 1
0x2631:036 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus Sequencer Product category i550 Read more about 0x2631:036 Parameter Function list: Abort sequence Default setting Not connected [0] M - A P C Data type U8 Display Code P400.36 Factor 1
0x2631:040 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:040 Parameter Function list: Load parameter set Default setting Not connected [0] M - A P C Data type U8 Display Code P400.40 Factor 1
0x2631:039 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:039 Parameter Function list: Activate ramp 2 Default setting Not connected [0] M - A P Data type U8 Display Code P400.39 Factor 1
0x2631:041 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:041 Parameter Function list: Select parameter set (bit 0) Default setting Not connected [0] M - A P C Data type U8 Display Code P400.41 Factor 1
0x2631:044 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:044 Parameter Function list: Activate fault 2 Default setting Not connected [0] M - A P Data type U8 Display Code P400.44 Factor 1
0x2631:043 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:043 Parameter Function list: Activate fault 1 Default setting Not connected [0] M - A P Data type U8 Display Code P400.43 Factor 1
0x2631:042 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:14 Fieldbus general Product category i550 Read more about 0x2631:042 Parameter Function list: Select parameter set (bit 1) Default setting Not connected [0] M - A P C Data type U8 Display Code P400.42 Factor 1