Перейти до основного вмісту

i510

The i510 cabinet frequency inverter is a compact control cabinet device with scalable functionality. It is versatile, reliable and easy to use.
The requirements of the Ecodesign Directive, Standard EN IEC 61800-9-2, are met.
Application areas: Conveyor drives, traveling drives, pumps, fans, agitators, ...

Highlights

  • Space saving design: 60 mm wide (up to 4 kW), 130 mm deep (up to 11 kW), with zero-clearance mounting
  • Innovative interaction (e.g. over WLAN) makes new record-breaking commissioning times and convenient diagnostics a reality
  • Special user-friendliness
Зображення
    Documentation
    Title Language Document type Version File
    Flyer i5xx cabinet frequency inverter EN Flyer 01/2025
    Error codes
    Fault ID: 12816
    Hex: 0x3210
    Description: Fault - DC bus overvoltage
    Keypad display: DC Bus OV
    Cause Remedy Severity/response

    DC-bus voltage has exceeded the error threshold for overvoltage due to a too high braking energy or a too high mains voltage. The error threshold (display in 0x2540:006 (P208.06) results from the setting of the rated mains voltage in 0x2540:001 (P208.01).

    Reduce dynamic performance of the load profile.

    Check mains voltage.

    Check settings for brake energy
    management.

    0x2541:001 (P706.01) = [0]: Connect brake resistor to the power unit and activate the integrated brake chopper

    Fault

    Fault ID: 12672
    Hex: 0x3180
    Description: UPS operation active
    Keypad display: UPS oper. active
    Cause Remedy Severity/response

    Operation on uninterrupted 1x230V current supply (UPS) has been activated: Only a reduced output current is provided.

    Switch back to operation with regular mains voltage

    Warning

    Fault ID: 12576
    Hex: 0x3120
    Description: Mains phase fault 
    Keypad display: Mains Phase fail
    Cause Remedy Severity/response

    Mains phase failure

    • Check wiring of the mains connection.
    • Check fuses.

    Fault

    Fault ID: 1030
    Hex: 1030
    Description: Undervoltage in the DC bus
    Keypad display: LU
    Cause Remedy Severity/response

    DC bus voltage is lower than specified in C0173.

    • Check mains voltage
    • Check supply cable

    cawc

    Fault ID: 1020
    Hex: 1020
    Description: Overvoltage in DC bus
    Keypad display: OU
    Cause Remedy Severity/response

    Braking energy is too high. (DC−bus voltage is higher than set in C0173.)

    • Use braking unit or regenerative module.
    • Check dimensioning of the brake resistance.
    Fault ID: 0016
    Hex: 0016
    Description: I2xt overload
    Keypad display: OC6
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: x018
    Hex: x018
    Description: I2xt overload advance warning
    Keypad display: OC8
    Cause Remedy Severity/response
    • Frequent and too long acceleration processes with motor overcurrent.
    • Permanent motor overload with Imotor >Irmotor

    Check drive dimensioning.

    Fault ID: 0015
    Hex: 0015
    Description: I x t overload
    Keypad display: OC5
    Cause Remedy Severity/response
    • Frequent and too long acceleration with overcurrent
    • Continuous overload with Imotor > 1.05 x Irx

    Check drive dimensioning.

    Fault ID: 0012
    Hex: 0012
    Description: Motor cable earth fault
    Keypad display: OC2
    Cause Remedy Severity/response

    One of the motor phases has
    earth contact.

    • Search for cause of short circuit.
    • Check motor cable.
    Fault ID: 0011
    Hex: 0011
    Description: Short circuit of motor cable
    Keypad display: OC1
    Cause Remedy Severity/response

    Short circuit

    Excessive capacitive charging
    current in the motor cable.

    • Search for cause of short circuit.
    • Check motor cable.

      Use motor cable which is shorter
      or of lower capacitance.

    Fault ID: 9090
    Hex: 0x2382
    Description: Fault - Device utilization (ixt) too high
    Keypad display: Ixt error
    Cause Remedy Severity/response

    Device utilisation (ixt) too high by frequent and too long acceleration processes.

    Check drive sizing. 

    • Reduce the maximum current of the inverter 0x6073 (P324.00). 
    • In case of high mass inertias, reduce maximum current of the inverter 0x6073 (P324.00) to 150 %.

    Fault (configurable)

    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Setting parameters: 0x2D40:005 (P135.05)

    Fault ID: 9040
    Hex: 0x2350
    Description: CiA: i²xt overload (thermal state)
    Keypad display: i2t motor
    Cause Remedy Severity/response

    Motor thermally overloaded, e. g. by an impermissible continuous current or by frequent or too long acceleration processes.

    Check drive sizing.

    • Check machine/driven mechanics for excessive load.
    • Check settings of the motor data.
    • Reduce values for slip compensation 0x2B09:001 (P315.01), 0x2B09:002 (P315.02) and oscillation damping 0x2B0A:001 (P318.01), 0x2B0A:002 (P318.02).

    Fault (configurable)

    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Setting parameters: 0x2D4B:003 (P308.03)

    Fault ID: 9024
    Hex: 0x2340
    Description: Short circuit at the motor end
    Keypad display: Motor shorted
    Cause Remedy Severity/response

    Short circuit of motor cable

    Check motor cable for short circuit.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Fault ID: 8992
    Hex: 0x2320
    Description: Short circuit or earth leakage at the motor end
    Keypad display: Earth leak
    Cause Remedy Severity/response
    • Short circuit/earth fault of motor cable
    • Capacitive charging current of the motor cable too high.
    • Check motor cable.
    • Check length of the motor cable.
    • Use shorter or lower-capacitance motor cable.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s

    Fault ID: 8784
    Hex: 0x2250
    Description: CiA: Continuous over current (internal)
    Keypad display: PU over current
    Cause Remedy Severity/response
    • Continuous overcurrent on the inverter/ motor side.
    • Overcurrent at the brake chopper (brake transistor).
    • DC bus relay has not been closed due to a malfunction.
    • Check motor and wiring for short circuits.
    • Check brake resistor and wiring.
    • Check motor switching.
    • Check settings of the motor data.

    Fault

    • The inverter is disabled immediately. The motor has no torque (is coasting).
    • The event can only be reset after a blocking time.

    Blocking time: 2 s