0x2601:002 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:12 Fieldbus general Product category i550 Read more about 0x2601:002 Parameter Keypad setpoints: Process controller setpoint Default setting 0.00 PID unit M r A P Data type I16 Display Code P202.02 Factor 100
0x2601:003 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:12 Fieldbus general Product category i550 Read more about 0x2601:003 Parameter Keypad setpoints: Torque setpoint Default setting 100.0 % M r A P Data type I16 Display Code P202.03 Factor 10
0x2636:003 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:003 Parameter Analog input 1: Max frequency value Default setting Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz M - A P Data type I16 Display Code P430.03 Factor 10
0x2636:002 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:002 Parameter Analog input 1: Min frequency value Default setting 0.0 Hz M - A P Data type I16 Display Code P430.02 Factor 10
0x2636:005 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:005 Parameter Analog input 1: Max PID value Default setting 100.00 PID unit M - A P Data type I16 Display Code P430.05 Factor 100
0x2636:004 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:004 Parameter Analog input 1: Min PID value on the model. Default setting 0.00 PID unit M - A P Data type I16 Display Code P430.04 Factor 100
0x2636:008 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:008 Parameter Analog input 1: Monitoring threshold Default setting 0.0 % M - A P Data type I16 Display Code P430.08 Factor 10
0x2636:012 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:012 Parameter Analog input 1: Max torque value Default setting 100.0 % M - A P Data type I16 Display Code P430.12 Factor 10
0x2636:011 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:011 Parameter Analog input 1: Min torque value Default setting 0.0 % M - A P Data type I16 Display Code P430.11 Factor 10
0x2637:002 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2637:002 Parameter Analog input 2: Min frequency value Default setting 0.0 Hz M - A P Data type I16 Display Code P431.02 Factor 10