0x2635:018 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:018 Parameter Inversion of digital outputs: NetWordOUT1.08 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:017 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:017 Parameter Inversion of digital outputs: NetWordOUT1.07 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:020 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:020 Parameter Inversion of digital outputs: NetWordOUT1.10 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:019 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:019 Parameter Inversion of digital outputs: NetWordOUT1.09 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:022 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:022 Parameter Inversion of digital outputs: NetWordOUT1.12 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:021 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:021 Parameter Inversion of digital outputs: NetWordOUT1.11 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:023 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:023 Parameter Inversion of digital outputs: NetWordOUT1.13 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:025 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:025 Parameter Inversion of digital outputs: NetWordOUT1.15 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2635:024 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2635:024 Parameter Inversion of digital outputs: NetWordOUT1.14 Default setting Not inverted [0] M - A P Data type U8 Factor 1
0x2636:003 Submitted by Pavol Krnáč on Mon, 20 Jul 2026 - 23:16 Fieldbus general Product category i550 Read more about 0x2636:003 Parameter Analog input 1: Max frequency value Default setting Device for 50-Hz mains: 50.0 Hz Device for 60-Hz mains: 60.0 Hz M - A P Data type I16 Display Code P430.03 Factor 10